Multi-Radius Grooved Copper Busbar Profiles
Video
Short Description
Cymber Metal supplies custom multi-radius grooved copper busbar profiles with central and side channels formed according to the customer drawing. These profiles can be supplied as long bars or cut segments for electrical contacts, cable supports, cooling assemblies and other conductive applications.
Product Overview
A multi-radius grooved copper busbar uses a shaped cross-section instead of a flat rectangular bar. The visible profile may include one central wide groove, smaller side grooves, raised dividing ribs and a rear locating step.
The grooved surfaces can be designed to match round conductors, cables, tubes or other mating components. Actual contact area, fit, thermal behavior and electrical performance depend on the mating-part geometry and complete assembly design.
Material options can be reviewed through Cymber Metal’s Pure Copper product range.
Key Features
- Multi-radius grooves designed for drawing-defined mating components.
- Central and side channels can support different conductor or tube geometries.
- Integrated locating steps or shoulders can be added where required.
- Available as long bars or cut-to-length conductor sections.
- Optional silver, tin or nickel plating for specified contact or assembly needs.
- Suitable for extrusion, drawing, machining or combined production routes after review.
Manufacturing & Quality Control
| Stage | Control Focus |
|---|---|
| Material Selection | Confirm copper grade, standard, condition and required documentation |
| Profile Forming | Review custom copper profile extrusion or another suitable forming route |
| Groove Development | Confirm groove radius, pitch, rib height, locating step and mating clearances |
| Sizing and Straightening | Control overall dimensions, straightness and profile consistency along the supplied length |
| Secondary Machining | Use fine machining for local grooves, holes, shoulders or end features |
| Surface Treatment | Confirm plating type, coverage and coating allowance for the mating assembly |
| Final Inspection | Check critical profile dimensions, surface condition, length and agreed material properties |
Inspection methods, sampling frequency and acceptance criteria should be agreed before production. The general inspection framework is described on the quality assurance page.
Typical Applications
| Application | Potential Component Role |
|---|---|
| Switchgear and Circuit Breakers | Grooved contact rails, clamp supports or conductive connection sections |
| Cable and Rod Supports | Saddle-style supports for drawing-defined round conductors |
| Cooling Assemblies | Copper profiles for tube-support or brazing-related components |
| IGBT and Power Electronics | Custom conductive and thermal-management components |
| Induction Heating Equipment | Profiled copper conductors and cooling interfaces |
| Industrial Electrical Systems | Special busbars, conductor rails and connection components |
Final suitability depends on conductor size, contact pressure, brazing or joining method, cooling conditions and the complete equipment design.
FAQ
It is a copper busbar with one or more longitudinal curved grooves instead of a flat rectangular surface. The grooves are designed to match specific cables, rods, tubes or contact components.
The number and shape of grooves are drawing-defined. A typical design may include one central large groove and two smaller side grooves, but equal-radius, unequal-radius and asymmetric arrangements are also possible.
Yes, the groove radius can be developed around the mating tube or conductor dimensions. The final fit must be checked against the tube diameter, clearance, plating allowance and assembly method.
It can be reviewed for cooling saddles, tube supports or brazed copper assemblies. The copper grade, joint design, thermal cycle, pressure conditions and brazing process must be confirmed before production.
C11000, C10200 and C10100 are typical options. Grade selection depends on conductivity, forming route, joining process, temperature and the applicable material standard.
Yes. A rear flat, shoulder, step or other locating feature can be incorporated when shown on the approved drawing. Its dimensions and flatness should be specified as critical characteristics where necessary.
Silver, tin or nickel plating can be reviewed for the full surface or selected areas. The coating thickness and coverage must be considered because plating changes the mating dimensions.
There is no universal current rating for the profile alone. Current capacity depends on copper grade, cross-sectional area, length, cooling, contact resistance, installation and allowable temperature rise.
Request a Quote
Please send the cross-section drawing, groove radii, pitch, overall width and thickness, copper grade, condition, length, quantity, surface treatment and inspection requirements. You can contact Cymber Metal for a drawing review and production feasibility check.