Custom I-Section Copper Busbar Profiles
Video
Short Description
Cymber Metal supplies custom I-section, H-section and double-flanged copper busbar profiles for drawing-defined electrical components. Profiles can be supplied as long bars or cut segments, with forming, machining and plating options reviewed according to the final application.
Product Overview
This profiled copper busbar uses a central web and extended upper and lower flanges to create a rigid, electrically continuous section. Depending on the approved drawing, the cross-section may be specified as an I-section, wide-flange H-section or another asymmetrical profile.
The flanged geometry can help integrate the conductor into motor rotor slots, busway supports, switchgear assemblies or conductor-rail systems. Final fit, current capacity, thermal behavior and mechanical performance must be confirmed against the complete assembly design.
Material options can be reviewed through Cymber Metal’s Pure Copper product range.
Key Features
- I-section or double-flanged geometry for drawing-defined electrical assemblies.
- Continuous copper section without an assembled joint through the conductor body.
- Suitable for long bars, cut segments and custom conductor components.
- Optional extrusion, drawing, machining, cutting and plating routes.
- Profile dimensions developed around the mating slot, support or rotor-core design.
- Copper grade and material condition selected according to conductivity, strength and forming requirements.
Manufacturing & Quality Control
| Stage | Control Focus |
|---|---|
| Material Selection | Confirm copper grade, standard, condition and required material documents |
| Profile Forming | Review custom copper profile extrusion or another suitable forming route |
| Drawing / Sizing | Control flange width, section height, web thickness and overall profile symmetry |
| Straightening | Review straightness, twist and flange parallelism according to the approved drawing |
| Cutting | Produce specified bar or segment lengths with deburring and end-condition requirements |
| Secondary Machining | Use fine machining for holes, threads, slots or local features |
| Surface Treatment | Confirm silver, tin or nickel plating requirements, including coverage and coating allowance |
| Final Inspection | Check critical dimensions, surface condition and specified conductivity or mechanical properties |
Inspection methods, sampling frequency and acceptance criteria should be agreed before production. The general inspection framework can be reviewed on the quality assurance page.
Typical Applications
| Application | Potential Component Role |
|---|---|
| Motor Rotor Assemblies | Rotor bars or damper-bar components subject to drawing and assembly validation |
| Wind Generator Equipment | Custom conductive profiles for generator-related assemblies |
| Rail Traction Motors | Profiled copper conductors and rotor-related components |
| Switchgear | Rigid main conductors and custom busbar sections |
| Sandwich Busways | High-current conductor profiles and connection sections |
| Industrial Conductor Rails | Rigid rail sections and joining components |
| Rectifier Equipment | Custom conductive bars for high-current electrical systems |
The final current, temperature and mechanical ratings depend on the complete assembly, contact design, cooling conditions and installation method.
FAQ
It is a profiled copper conductor with a central web and extended flanges. The section is designed according to the customer drawing to provide a specific combination of conductivity, stiffness, fit and mounting geometry.
The final description depends on the cross-section drawing. Similar products may be called I-section, H-section, double-flanged copper bar or profiled copper busbar. The approved technical drawing should determine the final product name.
It can be reviewed for rotor-bar or damper-bar applications when the cross-section, grade, condition, length, brazing requirements and operating temperature are provided. Rotor assembly compatibility must be validated by the equipment designer.
C11000, C10200 and C10100 are typical options. Other copper alloys may be considered where higher-temperature strength or special conductivity requirements apply. Final selection should follow the required standard and application conditions.
Yes. Long bars and cut segments can be reviewed according to the required profile size, saw-cut condition, end preparation, quantity and packing method.
Drawing-defined drilling, tapping, slots, chamfers and other local features can be reviewed after the basic profile is formed. The most practical route depends on the feature location, tolerance and production quantity.
Silver plating can be reviewed for applications requiring a specified contact or brazing surface. Coating thickness, coverage and dimensional allowance must be confirmed because plating can affect mating clearances.
There is no universal current rating for the profile alone. The rating depends on cross-sectional area, length, installation, cooling, joints, allowable temperature rise and the complete electrical design.
Request a Quote
Please send the cross-section drawing, copper grade, applicable standard, temper, section height, flange width, web and flange thickness, length, quantity, surface treatment and inspection requirements. You can contact Cymber Metal for a drawing review and production feasibility check.









