Custom Copper Stationary Blade Contact with L-Bent Terminal Wing

Short Description:

Parameter Specification / Customization Basis
Product Type Stationary blade contact / fixed copper contact terminal
Main Geometry Upright blade on a horizontal base with an L-bent terminal wing
Base Hole Pattern Four countersunk holes arranged in two rows, as illustrated
Terminal Wing Hole Single through-hole; diameter and edge treatment specified by drawing
Blade Lead-In Beveled or tapered geometry matched to the mating contact
Material Options C11000, C10200 or another approved copper grade, subject to confirmation
Material Temper Selected for forming feasibility and final mechanical requirements
Construction Requirement Integral blade-and-base construction can be specified; manufacturing route reviewed before production
Overall Dimensions Base length, width, blade height and terminal-wing length according to drawing
Blade Working Thickness Defined for the mating contact, including any plating allowance
Bend Geometry Angle, internal radius and terminal offset specified by drawing
Countersink Geometry Included angle, major diameter and depth matched to the specified fastener
Dimensional Tolerances Reviewed individually against functional datums and acceptance criteria
Contact Surface Roughness, flatness and edge requirements agreed for the working faces
Finish Options Unplated copper or specified silver, tin or nickel plating, subject to application review
Conductivity and Hardness Grade- and condition-dependent; acceptance values and test methods agreed when required
Electrical Ratings Established through equipment design and applicable validation

Product Detail

Product Tags

Video

Short Description

This custom copper stationary blade contact combines an upright blade, a four-hole countersunk base and a terminal wing bent approximately 90 degrees. Beveled blade edges provide a drawing-defined lead-in for the mating contact, while the bent wing provides an orthogonal bolted connection. Material grade, blade thickness, hole geometry, bend radius and surface treatment are specified according to the approved equipment drawing.

Product Overview

A copper stationary blade contact forms the fixed side of a blade-and-mating-contact interface. This design combines an inverted-T blade-and-base arrangement with an L-bent terminal wing, bringing the contact interface and busbar connection into different planes.

The illustrated component has four conical countersunk holes arranged in two rows on the base. The bent terminal wing includes a separate through-hole. The central blade has beveled edges, with its working thickness, lead-in geometry and engagement length defined by the mating assembly.

Suitable Pure Copper grades can be evaluated against conductivity, forming and contact requirements. C11000 and oxygen-free grades such as C10200 are potential material choices, subject to the specified standard, temper and order requirements.

An integral blade-and-base design can be specified where a one-piece current path is required. The starting profile, local machining and bending sequence must be reviewed before production. Electrical ratings and suitability for switching or arcing duty require equipment-level validation.

Key Features

Feature Design Relevance
Upright Contact Blade Provides a defined mating interface whose thickness and position can be controlled against the assembly drawing.
Four-Hole Countersunk Base Can accommodate flush-head fasteners when countersinks and screw geometry are correctly matched.
L-Bent Terminal Wing Provides an orthogonal busbar connection within the component’s overall geometry.
Beveled Lead-In Helps guide initial engagement within the permitted alignment range of the mating system.
Integral Blade-and-Base Option Allows a one-piece construction requirement to be considered during material and process planning.
Application-Specific Finishing Allows working faces, fastener seats and plated areas to be specified separately.

Manufacturing Process

The manufacturing plan coordinates the blade interface, formed terminal wing and mounting holes. The final operation sequence depends on the approved drawing and selected material condition.

Stage Manufacturing Activity Main Consideration
1. Engineering Review Review the blade, base, terminal wing, mating contact and mounting arrangement. Identify functional datums and dimensions that must be controlled after bending.
2. Material and Blank Selection Select the copper grade, temper and suitable starting form. A profiled blank may be evaluated for an integral blade-and-base design.
3. Local Machining Prepare the contour and remove material where required for the terminal-wing bend. Preserve the specified blade root and adequate material around the bend.
4. Terminal-Wing Forming Form the connection wing to the required angle and offset. Review bend radius, springback, tooling access and material condition.
5. Critical Feature Finishing Finish the blade faces, lead-in edges, countersinks and terminal hole. Post-forming machining may be selected to control spatial relationships.
6. Surface Treatment Deburr, clean and apply the ordered surface finish. Account for plating thickness on the final blade dimensions and mating fit.
7. Final Inspection Inspect the completed component against the agreed plan. Verify functional geometry in the finished condition.

The Fine Machining scope can be reviewed around the blade working faces, hole locations and connection surfaces. Specified coating requirements can also be discussed through the Busbar Plating Shop.

Manufacturing & Quality Control

Control Area Inspection / Review Acceptance Basis
Drawing Control Confirm revision, datums, blade working area and critical dimensions. Approved drawing and purchase order
Material Identification Review the ordered copper grade, temper and required supporting documents. Agreed material specification
Blade Thickness Measure the working section at defined locations, including coating where applicable. Finished-part thickness tolerance
Blade Geometry Check lead-in profile, edge condition and engagement dimensions. Mating-contact requirements
Formed Terminal Wing Check angle, offset and relevant positional relationships. Drawing-defined geometric requirements
Bend and Blade-Root Condition Examine accessible areas for visible forming or machining defects. Agreed inspection criteria; additional testing when specified
Countersunk Base Holes Check hole diameter, position, countersink angle and major diameter. Specified fastener and drawing requirements
Terminal Through-Hole Check diameter, location and edge treatment. Approved terminal connection details
Contact Surfaces Check specified roughness, flatness, cleanliness and burr condition. Working-face acceptance requirements
Plating, When Ordered Inspect thickness, coverage, masking and other agreed characteristics. Order-specific coating specification
Final Documentation Prepare agreed dimensional, material and inspection records. Contract requirements

Electrical resistance, conductivity, coating adhesion or additional nondestructive testing should be specified where required. Inspection scope and sampling must be agreed before production. Further quality information is available under Quality Assurance.

Typical Applications

Application Potential Function Required Design Review
Draw-Out Switchgear Assemblies Stationary blade interface with an orthogonal busbar connection Contact alignment, engagement length, temperature rise and insulation clearances
Circuit-Breaker Connection Bases Fixed conductive terminal within a drawing-defined connection system Equipment compatibility, contact pressure and mechanical loading
Plug-In Distribution Assemblies Blade-type connection between removable and stationary sections Mating-contact geometry, insertion force and operating cycles
Industrial Rectifier Cabinets Custom fixed contact or right-angle terminal connection Continuous current, cooling conditions and joint resistance
Renewable-Energy Power Equipment Drawing-based connection within converter or distribution assemblies Thermal performance, fault loading and environmental conditions

These are potential uses, not approvals for a particular equipment type. Load interruption, earthing-switch duty and arc exposure require separate design assessment and validation.

Frequently Asked Questions

What is a copper stationary blade contact?

A copper stationary blade contact is the fixed conductive blade engaged by a compatible moving or plug-in contact. This version combines the blade with a mounting base and a bent terminal wing. Its suitability depends on the mating interface, contact pressure, operating conditions and equipment design.

How does this design differ from a conventional copper busbar bracket?

The defining feature is its upright working blade, which must match a mating contact rather than serve only as a bolted connection. Blade thickness, surface condition, lead-in geometry and engagement position therefore require specific control alongside the base holes and bent terminal wing.

Are countersunk holes the same as counterbored holes?

No. A countersunk hole has a conical recess, typically matched to a flat-head screw. A counterbored hole has a cylindrical recess with a flat shoulder. The four base holes shown here are countersunk. Screw-head clearance depends on matching the countersink dimensions to the selected fastener.

Which copper grades can be considered for this contact?

C11000 and oxygen-free copper grades such as C10200 can be evaluated according to conductivity, forming and joining requirements. The exact grade, standard and temper should be stated on the order. Alternative alloys require a separate assessment because conductivity, strength and contact performance are not interchangeable.

Can the blade and base be manufactured as one piece?

An integral blade-and-base construction can be evaluated using a suitable profile or another approved starting form. Local machining and terminal-wing bending may form part of the route. The drawing should explicitly state any one-piece or no-weld requirement so manufacturing feasibility and inspection can be agreed.

Is silver plating necessary for the blade?

Silver plating may be specified for a contact interface, but it is not automatically required for every design. Coating selection depends on contact pressure, sliding duty, environment and mating materials. Specify plating composition, hardness where relevant, thickness, coverage and finished blade dimensions rather than relying on a generic finish description.

What tolerances can be achieved?

Tolerances must be reviewed against the drawing, particularly for blade thickness, working-face geometry, terminal-wing position and hole locations. Forming and plating can affect the final dimensions. Critical requirements should identify the inspection datums and whether acceptance applies before or after surface treatment.

Can this contact be used for high-current or high-voltage equipment?

Potentially, but neither rating can be established from its appearance alone. Current capability depends on conductor section, contact resistance and thermal conditions. Voltage suitability depends on the complete insulation arrangement and clearances. A stationary connection contact must not be assumed suitable for interrupting current or sustained arcing duty.

RFQ Information

Information Required Details to Provide
Drawing and Revision Dimensioned PDF and available STEP or other 3D model
Material Requirement Copper grade, applicable standard, temper and required properties
Blade Interface Working thickness, contact length, height, lead-in geometry and mating-contact details
Base Geometry Length, width, thickness and four-hole pattern
Countersink Details Through-hole diameter, included angle, major diameter and fastener specification
Bent Terminal Wing Length, angle, internal radius, offset and through-hole details
Critical Tolerances Datums, blade alignment, contact-face requirements and finished-condition dimensions
Surface Treatment Coating material, thickness, coverage, masking and contact-face requirements
Operating Conditions Current, thermal limits, contact pressure, insertion cycles and environmental exposure
Construction Requirement Any integral, one-piece or no-weld requirement
Quantity and Delivery Sample quantity, batch volume, destination and target delivery date
Quality Documents Required material certificates, inspection reports and testing scope

Send your drawing, mating-contact requirements and order quantity through Contact Us for technical review and quotation.


  • Previous:
  • Next:

  • Write your message here and send it to us