Inverted T-Section Copper Stationary Contact Block

Short Description:

Item Reference Specification
Product Type Inverted T-section copper stationary contact block
Main Geometry Upright contact blade with horizontal mounting base
Main Material Options C11000, C10200 or C10100 copper
Other Material Designations Cu-ETP, Cu-OF, TU1 or TU2, subject to the selected standard
Base Length 15–300 mm
Base Width 15–180 mm
Overall Height 15–160 mm
Upright Blade Thickness 2.5–30.0 mm
Base Flange Thickness 3.0–35.0 mm
Blade Thickness Tolerance Reference requirement: ±0.015–0.03 mm
Blade-to-Base Perpendicularity Reference requirement: ≤0.02 mm
Base Contact-Face Flatness Reference requirement: 0.015–0.025 mm
Blade Contact Surface Roughness Reference requirement: Ra 0.2–0.4 µm
Hardness Reference 90–130 HV, depending on grade and temper
Mounting Features Through-holes, tapped holes or counterbores according to drawing
Thread Range M4–M20 where internal threads are required
Contact Tip Rounded crest, chamfered lead-in or other specified profile
Surface Finish Bare copper, anti-tarnish treatment, silver plating, tin plating or nickel plating
Optional Silver Thickness Reference range: 10–30 µm
Conductivity Grade-specific requirement to be confirmed by material certificate and test method
Material Standards ASTM B187, ASTM B152, ASTM B133, EN 13601, EN 13605, JIS H3140 or GB/T 5585, where applicable
Supply Basis Approved drawing, confirmed material grade and agreed inspection plan

Product Detail

Product Tags

Video

Short Description

This inverted T-section copper stationary contact block is designed for drawing-defined plug-in and bolted electrical assemblies. The visible geometry includes a vertical blade section, a horizontal mounting base, rounded external edges and drilled mounting holes.

The component can be reviewed in C11000, C10200 or C10100 copper, with optional silver, tin or nickel plating according to the required contact surface, environment and assembly specification. Final material grade, dimensions, hole design, tolerances and finish should be confirmed by drawing.

Product Overview

An inverted T-section copper stationary contact block combines an upright contact blade with a horizontal mounting base. This structure can provide a compact interface for switchgear, disconnectors, earthing switches and other electrical assemblies where the contact position and mounting direction are fixed.

The photographs show a solid copper-colored part with a vertical blade, a horizontal base and rounded outer corners. Mounting holes are visible in the base and blade areas. The final hole type, whether through-hole, counterbore or tapped hole, must be defined by the approved drawing.

The upright blade can be specified with a rounded crest, lead-in chamfer or other engagement geometry when required by the mating contact. The base can also be customized with mounting holes, threaded features, counterbores or additional locating details.

For material selection, buyers can review Cymber Metal’s pure copper products. For custom hole patterns, profile finishing and drawing-based production, see our fine machining service.

The component should be evaluated as part of the complete electrical assembly. Current rating, temperature rise, contact resistance, dielectric clearance and short-circuit performance depend on the mating contact, mounting hardware, clamping force and equipment design.

Key Features

Feature Design Detail / Buyer Benefit
Inverted T-Section Combines a vertical contact blade with a horizontal mounting base in a compact profile.
Solid Copper Body Provides a continuous conductive body when the approved production route is a monoblock design. Final construction should be confirmed in the order documents.
Rounded Contact Crest A rounded blade crest can help match the mating contact geometry and reduce sharp transitions.
Lead-In Chamfer A drawing-defined chamfer can support guided engagement with a mating spring, tulip or blade contact.
Reinforced Blade Root The transition between the blade and base can be shaped to meet mechanical support and clearance requirements.
Multiple Mounting Options Holes, counterbores or internal threads can be customized according to the mating assembly.
Rounded External Corners Edge radii can be specified for handling, clearance and surface finishing requirements.
Surface Treatment Options Silver, tin or nickel plating can be considered for contact, environmental or wear-related requirements.
Drawing-Based Production Blade height, thickness, hole spacing, base dimensions and finish can be tailored to the equipment interface.

Manufacturing Process

The final process depends on the specified copper grade, temper, dimensions and tolerance. A near-net T-profile followed by CNC finishing is one possible production route.

Stage Process Main Control Points
Drawing Review Review the 2D drawing, 3D model and mating contact information. Blade geometry, base size, hole pattern, datums and critical tolerances
Material Preparation Select and cut suitable copper profile or copper stock. Grade, condition, cross-section and machining allowance
Profile Forming Produce or prepare the inverted T-section blank where required. Section accuracy, straightness, surface condition and material utilization
Cut to Length Cut the profile to the required length. Length tolerance, squareness and burr control
CNC Machining Finish the blade crest, chamfers, root transitions and mounting features. Perpendicularity, hole position, profile dimensions and surface finish
Thread or Counterbore Machining Add internal threads, counterbores or other mounting details when specified. Thread size, depth, gauge acceptance and mating hardware
Deburring Remove machining burrs from holes, edges and contact areas. Edge radius, cleanliness and absence of loose burrs
Surface Treatment Apply anti-tarnish treatment or specified plating. Coating coverage, thickness, masking and adhesion requirements
Final Inspection Inspect the finished contact block against the approved drawing. Dimensions, holes, flatness, finish, material records and packaging

For copper contact components requiring plated surfaces, Cymber Metal’s busbar plating shop can be referenced when discussing coating feasibility. Plating areas, thickness and masking should be agreed before production.

Manufacturing & Quality Control

The following inspection plan can be adapted to the customer’s drawing and equipment requirements.

Inspection Item Method / Control Approach Acceptance Basis
Material Grade Review material certificate and perform composition verification where required. Ordered grade and applicable material standard
Conductivity Use an agreed conductivity or resistivity test method with calibrated equipment. Grade-specific value stated in the purchase specification
Overall Dimensions Measure base length, width, height and blade thickness. Approved drawing and datum system
Blade Profile Check crest radius, chamfer, lead-in geometry and root transition. Drawing-defined profile requirements
Perpendicularity Use a coordinate measuring machine or suitable dimensional fixture. Blade-to-base perpendicularity tolerance
Mounting Holes Check hole diameter, position, spacing, depth and counterbore or thread details. Mating assembly requirements
Thread Inspection Use calibrated thread plug gauges where internal threads are specified. Applicable thread standard and gauge acceptance
Base Flatness Check the conductive mounting face on a suitable reference surface or measurement system. Drawing-defined flatness requirement
Surface Roughness Measure specified blade or mounting surfaces using a profilometer. Required Ra value on designated areas
Hardness Conduct Vickers hardness testing at agreed locations. Material temper and purchase specification
Plating Check coating thickness, coverage, adhesion and appearance where applicable. Agreed coating standard and order requirements
Surface Quality Visual inspection for scratches, cracks, burrs, dents and contamination. Approved visual acceptance criteria
Documentation Provide agreed material, dimensional and surface-treatment reports. Purchase order and inspection-plan requirements
Assembly Testing Arrange contact-resistance, temperature-rise or equipment-level tests when required. Complete assembly qualification plan

Cymber Metal’s Quality Assurance page can be used as a supporting quality reference. Certificates and inspection documents should be confirmed according to the actual order.

Typical Applications

These are potential application areas for engineering review, not guaranteed equipment ratings.

Application Potential Component Role Points to Confirm
Draw-Out Switchgear Stationary plug-in contact block for a withdrawable conductive interface Mating contact type, insertion force, clearances and current duty
Indoor Disconnectors Fixed blade contact or stationary conductive seat Contact geometry, operating travel and insulation coordination
Earthing Switches Stationary contact interface for the earthing path Fault-current requirements, mechanical endurance and grounding design
Motor Control Centers Compact fixed contact for plug-in feeder or busbar assemblies Feeder arrangement, thermal loading and mounting access
Air Circuit Breakers Conductive terminal or fixed blade interface Breaker manufacturer geometry, joint resistance and temperature rise
Energy Storage Cabinets Custom contact block for internal power connections DC current, insulation, vibration and thermal cycling
Industrial Power Supplies Fixed copper contact for a high-current internal connection Current waveform, frequency, enclosure conditions and service environment

Frequently Asked Questions

What is an inverted T-section copper contact block?

It is a copper electrical component with a vertical contact blade and a horizontal mounting base. The inverted T profile provides a compact way to combine a plug-in or blade interface with a fixed mounting surface.

Is this part a complete switchgear contact system?

No. It is a component used within a larger electrical assembly. The mating contact, insulation, mounting hardware, current path and equipment qualification determine the final performance.

Which copper grades are available?

C11000, C10200 and C10100 can be considered for pure copper contact components. The correct choice depends on conductivity, forming requirements, operating temperature, surface treatment and certification needs. The final grade should be confirmed against the customer’s standard.

Can the mounting holes be customized?

Yes. Hole diameter, spacing, depth, counterbore, thread type and location can be defined on the drawing. The photographs show visible holes, but they do not establish whether every feature is threaded or through-machined.

Can the upright blade height and thickness be changed?

Yes. Blade height, thickness, crest radius, chamfer and root geometry can be customized for the mating spring, tulip or knife contact. The available tolerance depends on the material condition and manufacturing route.

Can this contact block be silver-plated?

Silver plating can be reviewed for specified contact surfaces. The drawing should define plated areas, nominal thickness, masking, adhesion and inspection requirements. Plating does not by itself establish the contact resistance of the complete assembly.

Is this component suitable for high-voltage or high-current equipment?

It may be considered for suitable equipment after technical review. Current, voltage, temperature rise, creepage, clearance, short-circuit forces and mechanical endurance must be evaluated at the assembly level before selection.

What information is needed for a quotation?

Please provide the drawing or 3D model, copper grade, dimensions, hole and thread details, mating contact information, quantity, surface treatment, inspection documents and destination. These details allow the production route and acceptance criteria to be reviewed accurately.

Request a Quote

Required Information Details to Include
Drawing / 3D Model Dimensioned PDF drawing and STEP or equivalent model
Copper Grade C11000, C10200, C10100 or another specified grade
Profile Base size, blade height, blade thickness and root geometry
Mounting Details Hole diameter, spacing, thread, counterbore and depth
Contact Geometry Crest radius, lead-in chamfer, contact length and mating part
Tolerances Perpendicularity, flatness, position, surface roughness and profile tolerances
Surface Treatment Bare copper, anti-tarnish, silver, tin or nickel plating
Quantity Prototype quantity, production batch and expected annual demand
Application Switchgear, disconnector, earthing switch, MCC or other equipment
Inspection Documents Material certificate, dimensional report, plating report or third-party inspection
Delivery Details Destination, packaging and requested delivery schedule

Contact Cymber Metal for a drawing-based quotation. Please send the drawing and mating-interface requirements so material, machining, finishing and inspection can be reviewed together.


  • Previous:
  • Next:

  • Write your message here and send it to us