Custom round-to-flat copper busbar connector featuring a long cylindrical shank, a stepped female-threaded end and a flattened two-hole connection palm. The component provides a transition between a round conductor interface and a bolted flat connection. Copper grade, thread geometry, palm dimensions, hole spacing and surface finish are specified according to the approved drawing and mating assembly requirements.
Product Overview
This round-to-flat copper busbar connector combines two connection geometries in one elongated conductor: an internally threaded cylindrical end and a flat, two-hole terminal palm. The shaped transition connects the round shank to the wider palm, while the stepped socket end accommodates the specified mating threaded component.
Material selection starts with the required Pure Copper grade, temper and electrical properties. The design should also define the current-carrying contact surfaces, minimum section around the threaded bore, palm thickness and remaining material around the mounting holes.
A one-piece construction can be specified for manufacturing review. The production route, dimensional tolerances and inspection requirements are agreed against the drawing rather than inferred from the product’s external appearance.
Key Features
| Feature | Practical Value |
|---|---|
| Round-to-Flat Configuration | Connects cylindrical conductor geometry to a flat bolted interface. |
| Female-Threaded Socket | Accommodates a matching threaded component with defined engagement requirements. |
| Two-Hole Connection Palm | Provides two fastening locations and rotational restraint within the assembled joint. |
| Shaped Transition | Allows the round shank and wider terminal palm to be integrated into the specified conductor layout. |
| Stepped Cylindrical End | Provides a configurable interface for assembly positioning or mating-part clearance. |
| Drawing-Based Construction | Allows critical contact faces, tolerances and connection details to match the equipment design. |
| Optional Surface Treatment | Supports application-specific contact-surface and corrosion-protection requirements. |
Joint security depends on the complete fastening system, including bolt selection, preload, copper temper and service conditions. A two-hole pattern alone does not guarantee resistance to loosening.
Manufacturing Process
The manufacturing route is selected after reviewing the copper grade, section changes, overall length and required quantities. End forming or forging may be combined with machining where technically suitable.
| Stage | Process Scope |
|---|---|
| 1. Drawing Review | Confirm interfaces, dimensions, current-carrying sections, material and inspection requirements. |
| 2. Material Preparation | Select copper stock with the specified grade, temper and traceability requirements. |
| 3. Preform Production | Evaluate suitable stock preparation and local forming for the widened palm and end geometry. |
| 4. Cylindrical-End Machining | Machine the shank features, end steps, bore and internal thread. |
| 5. Palm Machining | Produce the contact faces, external profile, through-holes and transition details. |
| 6. Deburring and Finishing | Remove burrs and apply the specified edge treatment and surface finish. |
| 7. Optional Plating | Apply the approved coating system to defined surfaces when required. |
| 8. Final Inspection | Inspect agreed characteristics and prepare the specified shipment documentation. |
Threading, drilling and contact-face finishing can be reviewed through Cymber Metal’s Fine Machining service. Optional coating requirements can be discussed with the Busbar Plating Shop, including coating type, thickness, masking and post-plating dimensions.
Manufacturing & Quality Control
| Control Area | Inspection / Verification Scope |
|---|---|
| Material Identification | Verify the specified copper grade, temper and required material documentation. |
| Overall Dimensions | Check overall length, shank diameter, stepped-end dimensions and palm geometry. |
| Internal Thread | Verify thread form, pitch, class and usable engagement using the agreed inspection method. |
| Socket Wall Section | Check bore depth and the remaining material around the threaded socket. |
| Palm Hole Pattern | Inspect hole diameter, center distance, position and edge distance. |
| Contact Surfaces | Check specified flatness, surface texture and cleanliness on designated contact areas. |
| Interface Alignment | Inspect the relationship between the threaded-end axis, shank and palm datums. |
| Edges and Surface Condition | Check for burrs, sharp edges and unacceptable surface damage. |
| Plating, When Specified | Verify agreed coating thickness, coverage, masking and dimensional allowance. |
| Additional Testing | Conductivity, hardness or nondestructive testing can be included in the agreed inspection plan. |
| Shipment Records | Supply inspection and material records as specified in the purchase requirements. |
Inspection scope and acceptance criteria are established before production. See Quality Assurance for Cymber Metal’s quality-control approach.
Typical Applications
The following are potential applications. Final suitability depends on the equipment design and assembly validation.
| Application | Potential Connection Role | Main Design Considerations |
|---|---|---|
| Switchgear Assemblies | Transition between a round conductor and flat busbar connection | Contact area, clearances, temperature rise and fastening arrangement |
| GIS Conductor Assemblies | Custom internal conductor transition | Electric-field geometry, insulation coordination and separately specified sealing requirements |
| Vacuum Circuit-Breaker Assemblies | Drawing-specific terminal or conductor connection | OEM interface geometry, mechanical loading and contact requirements |
| Transformer and Reactor Bushings | Connection between a bushing conductor and a flat terminal interface | Thread engagement, installation loads and current-carrying surfaces |
| Disconnectors | Rigid conductor-to-terminal transition | Alignment, fastening security and operating loads |
| Industrial Power Equipment | Custom connections in rectifiers, converters or induction equipment | Duty cycle, cooling conditions and thermal expansion |
Frequently Asked Questions
It is a rigid copper conductor that transitions from a cylindrical section to a flattened terminal palm. This design also includes a female-threaded socket at the cylindrical end and two mounting holes in the palm.
A one-piece construction can be specified for review. Feasibility depends on the copper grade, section changes, dimensions and selected manufacturing route. Any requirement for a weld-free component should be stated explicitly on the drawing or purchase specification.
Select the grade according to conductivity, mechanical properties, forming requirements and service conditions. The applicable material standard and temper should be stated explicitly. Copper grades from different designation systems should not be treated as automatically interchangeable.
Specify the thread standard, nominal size, pitch, tolerance class, thread direction and effective engagement depth. The drawing should also identify the mating component, seating arrangement and electrical contact surfaces. Installation torque requires a joint-specific assessment.
Two fastening locations help position the joint and provide rotational restraint. Reliable service still depends on suitable hardware, controlled preload, contact-surface preparation and allowances for copper deformation and thermal cycling.
Silver or tin plating can be reviewed according to the application. Specify the coating system, thickness, plated areas and masking requirements. Thread dimensions and fit must account for any coating applied to the threaded interface.
Not automatically. An external step or annular relief does not establish a validated seal. Gas-tight service requires defined seal geometry, suitable sealing materials, surface requirements and assembly-level leak testing. The photos do not establish a voltage or pressure rating.
Provide a dimensioned drawing, copper grade, quantity, thread specification, palm hole pattern, contact-surface requirements and any plating or inspection requirements. Information about the mating components and operating environment helps resolve interface questions before production.
RFQ Information
| Required Information | Details to Provide |
|---|---|
| Drawing Files | Dimensioned PDF and STEP or another suitable 3D format, when available |
| Copper Material | Grade, material standard, temper and required properties |
| Quantity | Prototype quantity, order quantity and expected annual demand |
| Overall Geometry | Length, shank diameter, end steps and round-to-flat transition dimensions |
| Thread Details | Standard, size, pitch, class, direction and engagement depth |
| Socket Details | Bore depth, wall thickness and mating-component requirements |
| Palm Connection | Width, thickness, hole diameter, hole spacing and contact area |
| Critical Datums | Alignment, position and contact-face requirements |
| Surface Treatment | Bare copper or specified coating, thickness and masking |
| Service Conditions | Current duty, temperature, mechanical loads and installation environment |
| Quality Documentation | Required material records, inspection reports and additional testing |
| Delivery Requirements | Destination, packaging requirements and target delivery date |