Custom S-Offset Copper Tubular Busbar with Internal Threaded Ends

Short Description:

Parameter Specification / Customization Basis
Product Type Bent copper tubular busbar / conductor tube
Material Copper; grade and temper to be specified
Tube Construction Tube type and manufacturing condition to be confirmed by specification
Overall Geometry S-offset, Z-offset or other specified compound bend
Tube Dimensions Outside diameter, wall thickness and length per drawing
Bend Details Bend radius, angle, plane and offset distance per drawing
End Interfaces Stepped collars and internal threads as specified
Thread Details Standard, size, pitch, tolerance class and engagement depth per drawing
End Bore Features Counterbore, bore depth and seating geometry per drawing
Port Alignment End-face position, orientation and spatial offset per drawing
Surface Finish Bare copper or specified finish
Optional Coating Silver, tin or nickel plating subject to design review
Inspection Requirements Bend profile, port position, thread fit and any specified leak test

Product Detail

Product Tags

Video

Short Description

Custom bent copper tubular conductor with an offset profile, stepped end collars and internally threaded end interfaces as specified. The bend geometry, tube dimensions, thread details and material are defined by the approved drawing and mating assembly requirements.

Product Overview

This S-offset copper tubular busbar uses a curved tube body to connect two end interfaces positioned with an offset. The photos show stepped cylindrical ends and a female-threaded port; the product brief specifies internal threads at both ends. Thread standards, engagement depth and the exact construction of each end should be confirmed against the drawing.

The part may be considered for compact conductor layouts in switchgear, power equipment or water-cooled assemblies, subject to the assembly design and validation. A suitable Pure Copper grade should be selected according to conductivity, forming requirements and service conditions. The images alone do not establish pressure, leakage, voltage or current ratings.

Key Features

Feature Practical Value
Offset Tube Geometry Routes the conductor around space or interface constraints in an equipment layout.
Stepped End Collars Provide defined end geometry for the specified mating interfaces.
Internal Threaded Ports Allow threaded connections where required by the assembly design.
Tubular Conductor Form Provides a hollow internal section; actual flow or cooling use must be specified and validated.
Custom Bend Orientation Allows the bend plane, offset and terminal orientation to follow the drawing.
Post-Bend End Machining End dimensions and threads can be defined in relation to the formed tube geometry.
Drawing-Based Configuration Supports coordination of tube dimensions, bend position, interfaces and inspection criteria.

Manufacturing Process

The route should be selected after reviewing the drawing, tube specification, bend geometry and end interfaces. End machining and any pressure or leak testing depend on the order requirements.

Stage Process Scope
1. Drawing Review Confirm tube dimensions, bend planes, offset, end interfaces and critical datums.
2. Material Selection Specify copper grade, temper and required documentation.
3. Tube Preparation Prepare the specified tube stock and cut to a suitable blank length.
4. Bend Planning Review bend radius, sequence, tooling and deformation limits for the specified geometry.
5. Tube Bending Form the offset or compound bend using a route selected for the tube and drawing.
6. End Machining Machine end collars, counterbores and internal threads as specified.
7. Deburring and Cleaning Remove burrs and clean the tube and connection ports as required.
8. Optional Surface Treatment Apply specified plating or another approved finish if required.
9. Final Inspection Check the formed geometry, port positions, threads and any agreed test requirements.

Cymber Metal’s Fine Machining service is relevant to review for drawing-based end machining. If plating is required, specify coating type, thickness and coverage for review with the Busbar Plating Shop.

Manufacturing & Quality Control

Control Area Inspection / Verification Scope
Material Verify the specified copper grade and temper against the agreed purchasing documents.
Tube Dimensions Inspect outside diameter, wall thickness and cut length as specified.
Bend Profile Check bend angle, radius, plane and offset against drawing datums.
Bend Condition Visually inspect for unacceptable wrinkling, flattening, cracking or surface damage.
Port Position Measure end-to-end spacing, orientation and spatial position according to the drawing.
End Geometry Verify stepped diameters, counterbores, end faces and seating features.
Internal Threads Check thread standard, size, pitch and fit using the agreed method.
Surface Condition Check for burrs, contamination and handling damage.
Leak Testing Conduct only when required, using the agreed medium, pressure, method and acceptance criteria.
Documentation Provide material and inspection records as specified in the purchase requirements.

Inspection methods and acceptance criteria should be agreed before production. See Quality Assurance for Cymber Metal’s quality-control approach.

Typical Applications

These are potential applications based on the product geometry. Final suitability depends on the complete equipment design and validation requirements.

Application Potential Role Design Considerations
Switchgear Assemblies Offset conductor between connection points Electrical clearances, current duty, terminal fit and assembly space
Gas-Insulated Equipment Internal tubular conductor route Equipment-specific interfaces, insulation coordination and any separately validated sealing requirements
Circuit-Breaker Assemblies Formed connection tube or conductor transition Mating geometry, operating loads and electrical validation
Water-Cooled Power Equipment Potential tubular conductor or manifold connection Coolant compatibility, flow design, sealing and pressure testing
Induction Heating Equipment Formed conductor connection Frequency, current, thermal conditions and equipment interfaces
Power Converters and Rectifiers Compact offset conductor connection Current duty, temperature rise, cooling requirements and mechanical support

Frequently Asked Questions

What is an S-offset copper tubular busbar?

It is a copper tube formed with a compound bend to place its two end connections at an offset. This geometry can help route a conductor through a constrained assembly. The exact bend orientation, radius and port locations should be defined by the equipment drawing.

Are both ends internally threaded?

The product brief specifies internal threads at both ends, and the photos clearly show a female-threaded port at one end. Confirm whether both ports share the same thread and specify the standard, size, pitch, tolerance class and engagement depth.

Is the tube suitable for water cooling?

The hollow tube form may be considered for a cooling application, but the photos do not establish pressure capability or leak tightness. Specify the coolant, operating pressure, flow requirements, sealing method and leak-test criteria for engineering review.

Can the bend shape and offset be customized?

Yes. The drawing should define the bend plane, angle, centerline radius, straight-leg lengths, offset distance and end orientation. A 3D model is useful for confirming that the formed part will fit the intended assembly.

What copper grade should be used?

The grade and temper depend on conductivity, forming needs and operating conditions. State the material standard in the RFQ and confirm the selected condition is suitable for the required bend geometry and any post-forming operations.

Can the threaded ends be plated?

A specified coating can be reviewed. Identify the coating type, thickness, areas to be plated and any masking requirements. Thread fit and mating dimensions should account for coating buildup where applicable.

How should the formed tube be inspected?

Inspection can cover tube dimensions, bend profile, port position, end geometry and thread fit according to the drawing. If the part is used in a fluid or gas system, define the required leak-test method and acceptance criteria separately.

What information is needed for a quotation?

Provide a dimensioned drawing or 3D model, copper grade and temper, tube dimensions, bend geometry, thread specifications, quantity, tolerances, finish and inspection requirements. Include application details and mating-part information where available.

RFQ Information

Required Information Details to Provide
Drawing Dimensioned PDF and STEP or another suitable 3D format
Material Copper grade, standard, temper and required documentation
Quantity Prototype quantity, order quantity and expected annual demand
Tube Dimensions Outside diameter, wall thickness and overall length
Bend Geometry Bend radius, angle, plane, offset and straight-leg lengths
End Interfaces Collar dimensions, counterbores, threads and mating-part details
Thread Details Standard, size, pitch, class and engagement depth
Tolerances Port position, orientation, bend profile and end dimensions
Surface Treatment Bare copper or specified plating, thickness and coverage
Testing Dimensional inspection and any specified pressure or leak testing
Application Equipment type, current duty, cooling medium and service conditions
Delivery Destination, packaging requirements and target schedule

Send the drawing and requirements through Contact Us for material and manufacturing review.


  • Previous:
  • Next:

  • Write your message here and send it to us