Insulated Copper Conductive Post for Vacuum Circuit Breakers

Short Description:

Item Specification
Product Insulated Copper Conductive Post / Encapsulated VCB Terminal Assembly
Copper Material Options C11000 ETP copper, C10200 oxygen-free copper or C10100 oxygen-free electronic copper; grade and condition as specified
Optional Alloy Review C18150 may be reviewed where higher strength or softening resistance is required; it is a separate copper alloy, not an automatic equivalent to pure copper
Copper Feedstock Standards ASTM B152/B152M or ASTM B187/B187M for applicable plate or bar feedstock; EN 13601, JIS H3250, GB/T 5231 or other specifications by agreement
Assembly Standards Finished component to approved drawing and agreed test plan; IEC 62271-1, IEC 60137 or other equipment standards apply only when contractually specified
Overall Size Outer diameter 40–350 mm and height 60–600 mm indicative range; final envelope subject to design and process review
Conductor Configuration Solid post, ribbed insert or axial-window/cage-style conductor as specified
Exposed Terminal Faces Single central opening, five-hole pattern or custom contact and mounting arrangement
Insulation System Silicone-rubber or epoxy-resin encapsulation can be reviewed; compound, color, flammability, thermal class and dielectric requirements must be specified
Contact Surface Bare, passivated or selectively plated exposed copper faces; coating system and finished dimensions by agreement
Dimensional Tolerance Drawing-defined face flatness, parallelism, hole position, concentricity and overall dimensions; no universal ±0.02 mm tolerance is assumed
Electrical Acceptance Conductivity, dielectric withstand, insulation resistance, partial discharge and temperature-rise tests only when defined by the agreed product or assembly test plan
Inspection Material verification, dimensions, hole pattern, exposed faces, insulation coverage and surface condition; optional coating, X-ray, dielectric or partial-discharge checks as agreed
Documentation Material test certificate, dimensional report, coating records and electrical test reports as specified; certification scope subject to order confirmation

Product Detail

Product Tags

Video

Short Description

Cymber Metal supplies custom insulated copper conductive posts for vacuum circuit-breaker and switchgear assemblies. Each component combines a drawing-defined pure copper conductor with exposed terminal faces and an insulating body around the current-carrying structure.

Solid-body and axial-window configurations can be reviewed with single-hole or five-hole terminal faces. Copper grade, insulation compound, dimensions, hole pattern, plating and electrical acceptance requirements are confirmed from the customer drawing and equipment specification.

Key Features

  • Integrated copper conductor and insulating body for a drawing-defined switchgear interface.
  • Single-hole and five-hole exposed terminal-face options.
  • Solid cylindrical, ribbed or axial-window/cage-style configurations.
  • Custom copper grade, insulation compound, contact geometry and optional selective plating.
  • Inspection and electrical acceptance criteria defined for the specific component and equipment design.

Manufacturing & Quality Control

Stage Scope
Drawing and Electrical Review Confirm current path, terminal interfaces, hole patterns, insulation boundaries, creepage and clearance requirements, operating conditions and applicable tests
Copper Core Production Select the agreed copper grade and use CNC machining support for terminal faces, openings, slots, ribs and mounting features
Surface Preparation and Encapsulation Prepare the conductor surface and apply the specified insulation system using the approved molding or encapsulation process
Contact-Face Finishing Machine, clean or selectively plate exposed copper faces as specified, while protecting adjacent insulation
Final Inspection Check drawing-defined dimensions, exposed faces and insulation condition; perform agreed material, coating and electrical tests before protective packing

For inspection methods and available documentation, see our Quality Assurance page. Product-specific testing and acceptance criteria are confirmed before order placement.

Typical Applications

  • Insulated conductive posts in vacuum circuit-breaker assemblies.
  • Drawing-specific terminal conductors for embedded-pole systems.
  • Insulated transition components in medium- and high-voltage switchgear.
  • Custom conductor inserts for solid-insulated or compact power-distribution equipment.

This product is a component of an electrical assembly, not a complete vacuum circuit breaker or vacuum interrupter. Current rating, voltage class, dielectric performance, temperature rise and partial-discharge limits require validation in the intended component and equipment configuration.

Insulated Copper Conductive Post FAQ

What is an insulated copper conductive post?

It is a copper conductor combined with a molded or encapsulated insulating body, leaving selected copper faces exposed for electrical and mechanical connection. It can form part of a vacuum circuit-breaker, embedded-pole or switchgear assembly. Its exact function depends on the internal conductor geometry, terminal interfaces and equipment design.

Is this product a complete vacuum circuit breaker?

No. The supplied photographs show insulated conductive components with exposed copper terminals. They do not include the vacuum interrupter, operating mechanism, enclosure or complete tested breaker assembly. Product titles and descriptions should therefore identify the part as a conductive post, terminal assembly or conductor insert.

Which copper and insulation materials are available?

C11000, C10200 and C10100 copper can be reviewed against the required conductivity, condition and standard. C18150 may be considered separately for greater strength or softening resistance. Silicone-rubber or epoxy-resin insulation can be reviewed, but the exact compound, thermal class, flammability and dielectric properties must be stated in the order specification.

Can the conductor geometry and terminal-hole pattern be customized?

Yes. Solid, ribbed and axial-window/cage-style conductors can be reviewed from the customer's 2D and 3D files. Specify the exposed-face diameter, single-hole or multi-hole pattern, threads, slot geometry, internal interfaces, insulation boundary and all critical datums. Each structural variant should have its own part number.

What current and voltage ratings are available?

The photograph and copper grade do not establish a fixed current or voltage rating. Required current, duty cycle, allowable temperature rise, system voltage, impulse level, creepage distance and clearance must be provided. Suitability is then assessed against the complete equipment design and agreed verification tests.

Can partial-discharge and dielectric testing be provided?

These tests can be discussed when the test voltage, frequency, duration, partial-discharge limit, test circuit and applicable standard are defined. A blanket ≤5 pC or void-free claim should not be used for every component. Acceptance may require component testing, X-ray inspection or verification in the final equipment configuration.

Can the exposed copper faces be silver-plated?

Selective silver, tin or nickel plating can be reviewed for exposed contact faces. Specify the plated areas, coating thickness, undercoat, masking and coating standard. Flatness, hole dimensions and contact fit should state whether they apply before or after plating; coating alone does not determine joint resistance.

What inspection documents can be supplied?

Material certificates, dimensional reports, coating records and agreed electrical test reports can be supplied according to the order specification. X-ray inspection, conductivity, dielectric withstand, partial-discharge testing and third-party inspection require confirmed methods, sample scope and acceptance criteria. EN 10204 Type 3.1 documentation must be agreed before ordering.

Request a Quote

Contact Cymber Metal with your 2D/3D drawing, copper grade and condition, insulation material specification, overall dimensions, conductor geometry, terminal-hole pattern, quantity, plating requirements, operating current, system voltage, creepage and clearance requirements, electrical test plan, documentation needs, destination and target delivery date.


  • Previous:
  • Next:

  • Write your message here and send it to us