90-Degree Bent Copper Tubular Busbar with Threaded Ends
Video
Short Description
This bent copper tubular busbar features a 90-degree configuration, a hollow circular section and machined end connections. Internal threads and stepped end geometry can be specified to match the surrounding assembly. Material grade, wall thickness, bend radius, leg lengths and surface treatment are reviewed against the drawing for switchgear, power distribution and suitable water-cooled electrical applications.
Product Overview
A bent copper tubular busbar provides a conductive path that changes direction while retaining a hollow cross-section. This design combines an L-shaped body with machined connection features, allowing the conductor geometry and end interfaces to be defined within a single component drawing.
The photographed sample shows a rounded bend, two straight legs and a stepped external diameter near one end. The close-up photographs show an end bore and a clearly visible internal thread at the enlarged end. Exact dimensions, thread specifications and internal passage geometry require drawing confirmation.
Material options can be reviewed within our pure copper product range. C11000, C10200 and C10100 may be considered according to conductivity requirements, forming condition and any subsequent brazing or thermal processing.
Cymber Metal’s copper machining support can support drawing review for end diameters, threads, shoulders and other connection features. Current-carrying capacity, pressure suitability and equipment compatibility must be established for the intended assembly.
Key Features
| Feature | Product Detail / Buyer Consideration |
|---|---|
| 90-Degree Conductive Path | Changes the direction of a tubular conductor within a drawing-defined assembly |
| Hollow Circular Section | Provides an internal passage that may be used for cooling when the component is designed and tested for that purpose |
| Machined Threaded Connections | Thread size, class, engagement length and mating interface can be specified |
| Stepped End Geometry | End diameters and shoulders can be matched to connection or positioning requirements |
| Drawing-Based Bend Geometry | Bend radius, leg lengths and end orientation are defined around the installation envelope |
| Material Selection | Copper grade and condition are selected for electrical, forming and subsequent processing requirements |
| Continuous-Tube Bend Option | A bend formed from continuous tube can be specified where an elbow joint is not permitted |
| Optional Contact-Area Plating | Coating type, thickness and coverage can be reviewed for designated connection surfaces |
A continuous-tube construction requirement should be stated explicitly. Photographs alone do not establish the starting material route or verify the absence of joints.
Manufacturing Process
| Stage | Process / Control Focus |
|---|---|
| Technical Review | Confirm material, tube dimensions, bend radius, leg lengths, threads, sealing interfaces and critical tolerances |
| Starting Material Selection | Select suitable copper tube with the required grade, condition and documentation |
| Blank Preparation | Cut the tube to the required allowance and establish material identification |
| Forming Preparation | Review tooling, tube condition and the need for internal support during bending |
| Tube Bending | Form the required bend using a process suitable for the diameter, wall thickness and radius |
| Post-Bend Inspection | Check bend angle, leg position, ovality and accessible wall-thickness locations |
| End Machining | Machine the specified end diameters, shoulders, bores, counterbores and threads |
| Cleaning and Edge Finishing | Remove burrs and machining residue; clean accessible internal and external surfaces |
| Optional Surface Treatment | Apply the agreed coating or surface protection, accounting for final dimensional requirements |
| Final Verification and Packing | Inspect the ordered characteristics and protect threads, bores and contact surfaces for shipment |
For related finishing options, see our busbar plating shop. Coating coverage inside bores and threads requires separate review.
Manufacturing & Quality Control
| Inspection Area | Proposed Verification | Acceptance Basis |
|---|---|---|
| Material Identification | Review material documentation and agreed composition checks | Specified grade, standard and condition |
| Oxygen Content | Use an appropriate oxygen-analysis method when required | Specified limit and agreed test method |
| Starting Tube Dimensions | Check outside diameter, wall thickness and relevant tube condition | Approved starting-material specification |
| Bend Geometry | Measure bend angle, leg lengths and relative end positions | Drawing datums and tolerances |
| Bend Ovality | Measure the cross-section at agreed bend locations | Defined ovality formula and acceptance limit |
| Wall Thickness After Bending | Check accessible locations using an agreed method | Minimum permitted wall thickness |
| Machined End Dimensions | Measure end diameters, shoulders and counterbores | Approved drawing |
| Thread Quality | Use suitable gauges or an agreed inspection method | Thread standard, size, class and engagement length |
| Surface Condition | Inspect for unacceptable cracks, wrinkles, burrs and handling damage | Agreed workmanship criteria |
| Surface Roughness | Measure specified functional surfaces | Drawing requirements and measurement conditions |
| Conductivity | Perform testing when required by the order | Agreed value, test method and material condition |
| Leak / Pressure Testing | Conduct an agreed test for fluid-service components | Specified pressure, medium, duration and acceptance criteria |
| Additional Nondestructive Testing | Review suitable methods where required | Order-specific inspection plan |
| Plating Inspection | Check specified thickness, coverage and other coating characteristics | Approved coating specification |
| Documentation | Supply the agreed material and inspection records | Purchase-order requirements |
Routine composition screening alone should not be used to certify low oxygen content. Inspection scope, sampling and reporting are agreed before production. Further information is available on our quality assurance page.
Typical Applications
These are potential application areas. Final suitability depends on the equipment design, operating conditions and required qualification.
| Application Area | Potential Component Role | Requirements to Confirm |
|---|---|---|
| Gas-Insulated Switchgear | Bent tubular conductor between drawing-defined interfaces | Electric-field design, clearances, thermal performance and equipment qualification |
| Circuit Breaker Assemblies | Direction-changing conductive connection | Contact arrangement, connection loads and current duty |
| Power Distribution Equipment | Tubular busbar transition around installation constraints | Current rating, supports, temperature rise and fault-load requirements |
| Induction Heating Equipment | Water-cooled electrical conductor | Frequency, cooling flow, water quality and pressure requirements |
| Vacuum Melting / Crystal Growth Equipment | Custom power-and-cooling connection | Material grade, thermal cycling, cleanliness and joining requirements |
| Industrial Power Converters | Drawing-specific cooled conductor or connection tube | Electrical isolation of the cooling circuit, joint design and leakage criteria |
Frequently Asked Questions
A bent copper tubular busbar is a hollow copper conductor formed to change the direction of an electrical path. It can incorporate machined ends, threads and shoulders. The internal passage may also serve a cooling function when designed and tested for that application.
This component is specified around electrical conductor geometry and machined assembly interfaces, rather than a standard plumbing fitting connection. However, its electrical or pressure suitability still requires confirmation; copper material and an elbow shape alone do not establish a rating.
Grade selection depends on conductivity, forming condition, thermal processing and service requirements. C11000 may be considered for many electrical applications. Oxygen-free grades such as C10200 or C10100 may be preferable when subsequent processing raises concerns about hydrogen embrittlement in oxygen-bearing copper.
Not necessarily. Thread retention and fluid sealing are separate design requirements. Straight metric or BSPP threads commonly require a separate sealing arrangement. Tapered threads also need the correct mating geometry and assembly procedure. The sealing method must be defined in the drawing.
A bend formed from continuous copper tube can be specified, subject to geometry and forming review. State any restrictions on joints in the enquiry. A continuous bend removes that particular elbow joint but does not eliminate the need to inspect the tube, bend and end connections.
Potentially, provided the component and complete cooling circuit are designed for it. Please specify the medium, pressure, temperature, flow, water quality and leakage criteria. Bore continuity and hydraulic performance cannot be confirmed from the photographs alone.
Silver plating can be reviewed for designated connection areas. Please specify thickness, coverage, any underlayer and final thread or fit requirements. Internal surfaces and recessed features may need different coating and inspection arrangements from accessible external surfaces.
Neither rating is determined by the component’s shape alone. Current capability depends on conductive area, joints, cooling, frequency, ambient conditions and permissible temperature rise. Voltage suitability depends on the complete insulation system, clearances, field distribution and equipment testing.
Request a Quote
| Required Information | Details to Provide |
|---|---|
| Drawing / CAD File | Dimensioned PDF and STEP or other available CAD format |
| Material | Copper grade, applicable standard and required condition |
| Tube Dimensions | Outside diameter, wall thickness and minimum internal passage |
| Bend Geometry | Angle, centerline radius, leg lengths and end orientation |
| Connection Features | Thread size, pitch, class, usable depth, shoulders and counterbores |
| Critical Tolerances | Datums, dimensional limits and geometric requirements |
| Construction Requirements | Any restrictions on joints, brazing or welding |
| Electrical Conditions | Current, frequency, duty cycle and temperature-rise requirements |
| Cooling Conditions | Medium, pressure, temperature, flow and leakage criteria, if applicable |
| Surface Treatment | Coating type, thickness, coverage and contact-surface requirements |
| Inspection Documents | Required material records, dimensional reports and special tests |
| Quantity and Delivery | Prototype / batch quantity, destination and requested schedule |
Contact Cymber Metal for a custom conductor quotation with your drawing, material specification and operating requirements.