Custom Flanged Copper Terminal with D-Cut Stem
Video
Short Description
This custom flanged copper terminal combines a circular mounting flange, a cylindrical transition section, and an upper D-cut stem with a flat connection pad and two transverse tapped holes. The flange includes a central axial threaded hole and four mounting holes with side-open recessed pockets on the underside.
The component provides a drawing-based conductive interface for busbar connections, bushing assemblies, and other electrical equipment. Material options include C11000, C10200, and C10100 copper, with machining, thread fit, contact-surface finish, and optional plating reviewed against the application requirements.
Product Overview
A flanged copper terminal combines a conductive post with a mounting flange, allowing the electrical connection and mechanical attachment interfaces to be defined within one component design.
The pictured version has a circular base with four peripheral mounting holes. Side-open recessed pockets on the underside provide space around these holes for the specified mounting hardware. A central axial threaded hole offers an additional attachment interface where required by the assembly design.
The upper stem has a milled flat that creates a D-shaped section. This flat provides a mating surface for a busbar or another conductor, while two transverse tapped holes support the specified bolted connection. A shoulder below the flat can serve as a locating surface when matched to the adjoining part.
A one-piece machined construction can be specified to avoid a separate flange-to-stem joint. Starting material, machining sequence, and final construction should be confirmed during drawing review.
Explore Cymber Metal’s pure copper products for material options and Fine Machining for custom component processing.
Key Features
| Feature | Design Purpose | Engineering Consideration |
|---|---|---|
| Circular Mounting Flange | Provides a defined mounting interface around the conductive post | Flange thickness, bolt circle, and support conditions must suit the applied loads |
| Central Axial Thread | Provides a stud or fastener attachment interface | Thread engagement, tightening torque, and copper condition require review |
| Four Peripheral Mounting Holes | Supports a distributed fastening arrangement | Hole positions and access must match the mating assembly |
| Side-Open Recessed Pockets | Provides local clearance for specified mounting hardware | Pocket depth, remaining wall thickness, and fastener seating must be defined |
| D-Cut Upper Stem | Creates a flat surface for a mating conductor | Contact area, orientation, flatness, and surface finish require control |
| Dual Transverse Tapped Holes | Supports a two-fastener connection layout | Thread strength and permitted bolt preload depend on the complete joint |
| Lower Contact-Pad Shoulder | Can provide a locating or supporting reference | Its locating function depends on the mating conductor geometry |
| Optional One-Piece Construction | Avoids a separate flange-to-stem joining operation | Does not independently establish electrical or mechanical ratings |
| Optional Plating | Adapts the contact surface to the specified joint environment | Coating thickness, masking, and final thread fit must be coordinated |
Manufacturing Process
The machining route should maintain the relationship between the flange datum, stem axis, contact pad, and threaded features.
| Stage | Process Scope | Main Review Point |
|---|---|---|
| Drawing and Datum Review | Define flange surfaces, stem axis, contact pad, holes, and thread requirements | Establish measurable functional tolerances and inspection references |
| Material Selection | Select copper grade, condition, and suitable starting stock | Balance conductivity, thread strength, machinability, and material cost |
| Blank Preparation | Prepare stock with appropriate machining allowance | Maintain material identification and sufficient allowance for finishing |
| Turning | Produce the flange, stem, shoulders, and axial features | Control diameters and their relationship to the selected datum axis |
| Milling | Produce the upper flat, shoulder, and flange recesses | Control contact-pad orientation, pocket geometry, and hole locations |
| Thread Production | Machine the axial and transverse internal threads | Define thread class, usable engagement, and blind-hole depth where applicable |
| Deburring and Finishing | Finish contact surfaces and remove burrs at hole and thread exits | Pay particular attention to transverse holes exiting through curved surfaces |
| Surface Treatment | Apply the agreed cleaning, anti-tarnish treatment, or plating | Account for coating buildup and any masked contact or threaded areas |
| Final Inspection and Packing | Verify agreed characteristics and protect finished surfaces | Prevent damage to threads, flange seating faces, and the contact pad |
Turn-mill machining or coordinated turning and milling may be selected according to the design. Machine configuration and setup count should be confirmed rather than assumed from the finished geometry.
For coating-related processing, review Cymber Metal’s Busbar Plating Shop. Finish selection should consider the mating material, operating environment, and required joint performance.
Manufacturing & Quality Control
The inspection plan should identify critical characteristics, measurement methods, and sampling requirements before production.
| Control Area | Inspection / Verification | Acceptance Basis |
|---|---|---|
| Material Identification | Review grade, condition, and material documentation | Approved material specification and order requirements |
| Material Properties | Verify conductivity, hardness, or composition where specified | Agreed test methods and grade-specific acceptance criteria |
| Overall Dimensions | Measure flange diameter, thickness, stem diameter, and total height | Approved drawing |
| Flange Mounting Pattern | Check hole diameter, bolt-circle location, spacing, and recess dimensions | Drawing datums and positional requirements |
| Central Thread | Check thread size, pitch, engagement depth, and specified axis relationship | Approved thread specification and geometric requirements |
| Transverse Threads | Check thread fit, center spacing, location, and usable engagement | Drawing and agreed thread-gauging plan |
| D-Cut Contact Pad | Check flatness, shoulder position, and perpendicularity to the flange datum | Defined functional-surface requirements |
| Surface Finish | Measure specified roughness and inspect contact and mounting surfaces | Surface-specific acceptance limits |
| Burr Control | Inspect pocket edges, hole intersections, and curved-surface thread exits | Agreed burr and edge-break requirements |
| Coating Quality | Check thickness, coverage, adhesion, and masked areas where specified | Approved coating specification |
| Internal Soundness | Perform ultrasonic or other suitable inspection when required and technically applicable | Agreed procedure, coverage, and acceptance criteria |
| Assembly Validation | Evaluate thread loading, joint resistance, or temperature rise where required | Actual mating parts and an agreed test procedure |
| Traceability and Records | Review batch identification and required inspection reports | Agreed documentation package |
Review our Quality Assurance page for background on Cymber Metal’s quality approach. Product-specific testing, traceability, and documentation requirements should be confirmed before ordering.
Typical Applications
These are potential application areas, subject to equipment-specific design review and qualification. The component is not assigned a universal voltage, current, short-circuit, or pressure-sealing rating.
| Application | Potential Component Role | Required Confirmation |
|---|---|---|
| Vacuum Circuit-Breaker Pole Assemblies | Conductive terminal or transition component within a pole assembly | Electrical interface, temperature rise, mechanical loading, and dielectric design |
| Gas-Insulated Switchgear Bushing Assemblies | Conductive connection between a bushing interface and busbar | Insulation coordination, gas compatibility, sealing arrangement, and joint performance |
| Post-Insulator Busbar Supports | Flanged connection post with a flat busbar interface | Insulator loading, bolt preload, mounting geometry, and clearances |
| Epoxy-Embedded Electrical Assemblies | Conductive insert with drawing-specific mounting features | Resin compatibility, thermal cycling, electric-field control, and retention testing |
| Industrial Power Converters | Custom conductive transition terminal | Current duty, cooling conditions, connection resistance, and mounting loads |
| Induction Power Equipment | Connection post between conductors or equipment interfaces | Frequency-dependent losses, thermal behavior, vibration, and joint qualification |
FAQ
A flanged copper terminal is a conductive component that combines a mounting flange with a terminal post. This version includes a D-cut upper contact pad, two transverse tapped holes, a central axial thread, and four flange mounting holes. It is a connection component, not a complete insulating bushing or switching device.
The flat creates a mating surface for a busbar or another conductor. Its orientation allows the connection face to be positioned relative to the flange. The shoulder below the flat can provide a locating reference, but contact pressure, alignment, and mechanical support depend on the complete bolted-joint design.
The design provides a central axial threaded interface and four peripheral mounting holes. The equipment drawing determines which features are used and how loads are distributed. Fastener access, engagement length, seating surfaces, tightening sequence, and permitted torque should be established for the actual assembly.
They may contribute to mechanical retention if incorporated into a suitable embedded design, but their presence alone does not establish pull-out or anti-rotation strength. Resin properties, pocket geometry, cure conditions, thermal cycling, and electric-field requirements must be considered. Retention performance requires validation against defined acceptance criteria.
A one-piece construction can be evaluated from suitable solid stock. This avoids a separate flange-to-stem joint, but it does not guarantee resistance to every mechanical or thermal load. Final feasibility depends on dimensions, stock availability, material condition, machining access, and the required inspection scope.
C11000, C10200, and C10100 can be evaluated for conductive terminal applications. Material condition and thread loading are important alongside conductivity. C10400, C10700, C14500, or C18150 may be considered for different machining, strength, or thermal requirements, but they should not be treated as interchangeable grades.
No. Equipment voltage and short-circuit capability cannot be established from the terminal’s shape or material alone. Suitability depends on insulation coordination, conductor arrangement, temperature rise, mechanical forces, mounting conditions, and applicable equipment tests. Any rating must be supported by the complete assembly design and validation.
Silver, tin, or nickel plating can be evaluated according to the application. The drawing should define thickness, coverage, masking, and final dimensional requirements. Plating inside threaded holes can change fit, so thread allowances, coating control, and post-coating inspection need to be agreed before production.
Request a Quote
| Required Information | Details to Provide |
|---|---|
| Drawing | Dimensioned 2D drawing and, where available, a 3D model |
| Material | Copper grade, standard, condition, and required properties |
| Construction | One-piece requirement or any permitted alternative construction |
| Main Dimensions | Flange diameter and thickness, stem diameter, and total height |
| Mounting Pattern | Bolt-circle diameter, hole count, hole sizes, and recess details |
| Central Thread | Size, pitch, class, depth, engagement, and axis requirements |
| Transverse Threads | Size, spacing, position, thread class, and engagement length |
| Contact Pad | Flat dimensions, shoulder location, flatness, roughness, and orientation |
| Surface Treatment | Bare copper or specified coating, thickness, coverage, and masking |
| Operating Conditions | Current, voltage, frequency, temperature, environment, and mechanical loads |
| Assembly Requirements | Mating parts, fastener specifications, installation torque, and mounting method |
| Inspection and Documents | Material records, dimensional reports, coating checks, and any special tests |
| Quantity and Delivery | Sample quantity, batch volume, annual demand, destination, packing, and requested schedule |
Contact Cymber Metal for a drawing-based quotation covering material selection, machining feasibility, thread requirements, surface treatment, and inspection planning.