Cold-Drawn Pure Copper Inverted T-Profile Busbar Series
Video
Short Description
This cold-drawn pure copper inverted T-profile series is designed for electrical assemblies that require a continuous T-section with a dual-flange base and vertical web. Available in equal-wall, thick-web, thin-base and asymmetric configurations, the profiles can be supplied with flat-top or bullnose edges.
Typical uses include switchgear knife contacts, MCC drawer connections, circuit-breaker terminals, sandwich busway branch joints and high-rigidity copper busbars. Grade, temper, dimensions, edge geometry, plating and cut length can be customized according to the approved drawing.
Product Overview
The inverted T-profile is formed as a continuous copper section rather than assembled from two separately welded bars. The dual-flange base provides a broad mounting and contact surface, while the vertical web supplies height, alignment and structural stiffness.
Flat-top edges can be specified for orthogonal busbar lapping. Bullnose edges may be selected where smoother insertion guidance or rounded contact geometry is required. Equal-wall, thick-web/thin-base, thin-web/thick-base and offset configurations are available for different electrical and mechanical layouts.
For general material information, visit Cymber Metal’s Pure Copper product range.
All dimensions, current classes and tolerances are indicative enquiry ranges. Final values require drawing review, material confirmation and application evaluation.
Key Features
| Feature | Description |
|---|---|
| Continuous T-Section | Monoblock profile formed from one copper section, avoiding a separately welded T-junction. |
| Dual-Flange Base | Broad base geometry for mounting, positioning and conductive contact. |
| Vertical Web | Provides section height, alignment and additional cooling perimeter. |
| Wall Configurations | Equal-wall, thick-web, thin-base and asymmetric offset layouts available. |
| Top Edge Options | Flat-top or bullnose edge according to insertion, contact and assembly requirements. |
| Copper Grade Options | C11000, C10200, C10100 and other agreed copper grades. |
| Temper Options | Hard-drawn H02/H04 or annealed O60 condition. |
| Surface Treatment | Bright copper, passivation, silver, tin or nickel plating subject to review. |
| Custom Dimensions | Base width, total height, web thickness, flange thickness and offset can be customized. |
| Secondary Machining | Drilling, tapping, punching, chamfering, deburring and CNC machining available. |
Manufacturing & Quality Control
Manufacturing Process
| Process Stage | Description |
|---|---|
| Material Selection | C11000, C10200, C10100 or another specified copper grade is selected according to conductivity, temper, joining and application requirements. |
| Billet Preparation | Copper billets are prepared with controlled composition and internal quality according to the agreed material specification. |
| Hot Extrusion | The billet is extruded into a preliminary T-section or near-net profile. |
| T-Section Cold Drawing | Dedicated tungsten-carbide or equivalent forming dies control the web, base flange, wall thickness and top-edge geometry. |
| Unequal-Wall Control | Die and drawing parameters are adjusted for equal-wall, thick-web, thin-base or asymmetric sections. |
| Straightening | Multi-roll straightening controls web alignment, base flatness and overall straightness. |
| Cutting | Precision cold sawing produces bars or cut segments according to the required length. |
| Secondary Machining | Base drilling, tapping, punching, chamfering, deburring and CNC machining can be added after profile forming. |
| Plating and Finishing | Silver, tin or nickel plating can be reviewed according to the electrical and environmental requirements. |
| Temper Control | Hard-temper material can be supplied as drawn; annealed material can be supplied after controlled heat treatment. |
For custom profile tooling and section development, see custom copper profile extrusion support.
Quality Control System
| Inspection Item | Quality Control Method |
|---|---|
| Material Traceability | Traceability from cast heat or billet through extrusion, drawing, straightening, cutting and finishing. |
| Chemical Composition | Optical emission spectroscopy or another agreed method according to the selected grade. |
| Electrical Conductivity | Digital conductivity measurement using a suitable test method. |
| Hardness | Vickers or equivalent hardness testing for the specified temper. |
| T-Section Geometry | Profile projector or CMM measurement of base width, web height, wall thickness and offset. |
| Web Perpendicularity | Inspection of the web-to-base 90° relationship using precision measurement equipment. |
| Top-Edge Geometry | Verification of flat-top dimensions or bullnose radius according to the drawing. |
| Root Area | Inspection of root radius, transitions and visible surface condition. |
| Internal Soundness | Ultrasonic inspection can be discussed for critical or larger sections. |
| Flatness and Straightness | Measurement of base flatness, web alignment and full-length straightness. |
| Surface Quality | Visual inspection for scratches, dents, cracks, oxidation and other visible defects. |
| Documentation | Material certificates, dimensional reports and process records available according to order requirements. |
| Third-Party Inspection | SGS or other third-party inspection can be arranged when required. |
Cymber Metal’s quality assurance system supports material verification, dimensional inspection and technical documentation.
Typical Applications
| Application | Typical Use | Design Considerations |
|---|---|---|
| LV and MV Switchgear | Stationary knife contact blades and conductive switching interfaces | Confirm current, insertion force, contact pressure, plating and insulation clearance. |
| MCC Drawers | Flat-top or bullnose inverted T-profile contact blades | Edge geometry should match the mating contact and insertion path. |
| Circuit Breakers | Orthogonal transition blocks and outgoing terminal connectors | Confirm terminal layout, web height, base width and joining method. |
| Vacuum Circuit Breakers | Copper T-section conductive interfaces and mounting profiles | Review current, temperature rise, contact arrangement and assembly clearance. |
| Sandwich Busways | T-branch joints and conductive branch connection sections | Confirm branch geometry, fixing method, insulation and installation alignment. |
| Wind Inverters | High-rigidity T-section main busbars and connection parts | Check current, thermal cycling, vibration and mechanical support. |
| Photovoltaic Inverters | High-conductivity copper power distribution sections | Confirm enclosure space, temperature rise, plating and connection method. |
| Industrial Rectifier Cabinets | T-profile busbars and orthogonal copper connectors | Review current capacity, heat dissipation and fastening details. |
| Energy-Storage Equipment | Copper connection and support profiles | Confirm short-circuit forces, temperature and insulation requirements. |
| Custom Electrical Equipment | Special T-sections for customer-designed systems | Provide a 2D or 3D drawing for manufacturability review. |
The final grade, temper, profile geometry and plating should be selected according to current, temperature, mechanical load, mating contact and installation conditions.
FAQ
It is a copper electrical profile with a broad horizontal base flange and a vertical web, creating an inverted T-shaped cross-section. The design combines a conductive base with a raised alignment or contact section.
Common options include C11000, C10200 and C10100, together with Cu-ETP, Cu-OF, T2, TU1 and TU2 equivalents. C10400, C10700 or C18150 may be reviewed for applications requiring additional thermal or mechanical performance.
A flat-top design has a straight upper edge and is often used for orthogonal lapping or defined contact surfaces. A bullnose design has a rounded upper edge and may support smoother insertion or rounded contact geometry. The choice depends on the mating component.
Yes. The series can be designed with equal wall thickness, a thick web with a thin base, a thin web with a thick base or offset flange dimensions. The drawing should identify the required web, flange and centerline dimensions.
The profile is designed as a continuous extruded and drawn section. This avoids relying on a separate welded junction between the web and base. The final forming route, temper and inspection plan should be confirmed for each order.
It can be evaluated for stationary knife contacts and conductive switching interfaces. Contact pressure, insertion force, current, temperature rise, surface treatment, mating geometry and insulation clearance must be checked before final approval.
Yes. Full or selective silver plating, tin plating or nickel plating can be reviewed. Drilling, tapping, punching, chamfering, deburring and CNC machining are also available according to the approved drawing.
Please provide the copper grade, standard, cross-section drawing, base width, total height, web and flange thickness, top-edge geometry, tolerance, length, quantity, plating, inspection documents and destination country.
Request a Quote
Cymber Metal can review this inverted T-profile as a raw drawn section, cut contact blade, plated busbar component or further-machined electrical part.
| Required Information | Details |
|---|---|
| Drawing | 2D or 3D cross-section and assembly drawing |
| Material | Copper grade, equivalent grade and applicable standard |
| Geometry | Base width, total height, web thickness, flange thickness and offset |
| Top Edge | Flat-top, bullnose or other specified edge geometry |
| Tolerance | Wall thickness, perpendicularity, flatness, radius and surface roughness |
| Temper | H02/H04 hard temper or O60 annealed condition |
| Length | Bar length or cut-segment requirements |
| Quantity | Sample quantity, production quantity and estimated annual demand |
| Surface Treatment | Bare copper, passivation, silver, tin or nickel plating |
| Secondary Processing | Drilling, tapping, punching, chamfering, deburring or CNC machining |
| Inspection Documents | MTC, dimensional report, conductivity data, RoHS, REACH or third-party inspection |
| Delivery Details | Destination country and packing requirements |
For technical review and quotation, contact Cymber Metal.